Fire-resistant drywall is not just a special board. It is part of a full wall or ceiling system that is built and tested to resist fire for a set period, such as 1 hour or 2 hours. In Missouri City, TX, this kind of drywall is often used in garages, furnace rooms, shared walls, corridors, and stairwells. The board alone does not create the rating. The framing, fasteners, joints, layers, insulation, and seals around pipes and wires all matter.
The most common fire-rated board is 5/8-inch Type X drywall. A recent U.S. pricing guide lists it at $18 to $22 per sheet before installation. Installed costs vary based on labor, project size, access, finishing, and whether old material must be removed or framing repaired. A separate commercial guide gives a broad range of $2.40 to $8.50 per square foot across drywall types and finish levels. That range is only a budgeting reference, not a Missouri City quote.
Type X and Type C are both fire-resistant gypsum boards, but they are not automatically interchangeable. Type C is made for some assemblies that need greater fire resistance or specific ceiling designs. Multi-layer systems may use two or more layers of board with staggered joints and separate fastening patterns. Mineral wool insulation, fire-stop sealant, and careful treatment around electrical boxes, ducts, and pipes can also be required. The tested assembly design decides what goes in, not the board label alone.
Request a free quote from Missouri City Drywall Contractors.
Fire-Resistant Drywall Installation in Missouri City, TX: Type X Walls, Ceilings, and Rated Assemblies
Get Your Free Drywall Estimate
Wall, Ceiling & Fire-Separation Services in Missouri City, TX
Type X Fire-Rated Drywall Installation
Type X drywall contains a noncombustible gypsum core reinforced to improve fire resistance. Its rating depends on the tested wall or ceiling assembly, so the board alone does not establish a one-hour or two-hour rating.


A wall or ceiling between an attached garage and living space forms a fire-separation boundary. The required construction depends on the building layout and applicable code provisions, including whether habitable rooms sit above the garage.




Garage-to-House Fire Separation Walls & Ceilings
Fire-Rated Wall Assemblies (1-Hour and 2-Hour)


Fire-Rated Ceiling Assemblies
Fire-rated ceilings protect spaces above them and can form part of a floor-ceiling assembly. The required rating and construction depend on the building design, the space above, and the tested system specified for the project.


Shared Wall & Party Wall Fire Separation
Shared walls separate neighboring units and can form part of a building’s required fire separation. Their construction may include multiple layers of gypsum board, independent framing, insulation, or a specific wall system, depending on the approved design.


Fire-Rated Corridors, Stairwells & Shaft Walls
Corridors, stairwells, and shafts can serve as protected paths or enclosures within a building. Their fire-resistance requirements depend on the building plan and applicable code provisions, so we use the project documents to establish the specified assembly.
A one-hour or two-hour rating applies to a tested wall assembly, not simply to a type of drywall. The assembly may specify board layers, stud material and spacing, insulation, fasteners, joint locations, and treatment around openings.
5/8-Inch Type X Drywall


We use 5/8-inch Type X gypsum board where plans or applicable codes call for a fire-resistance-rated assembly. Its specially formulated core helps the board retain strength longer during fire exposure than standard gypsum board.
A panel alone does not establish a rated wall or ceiling; the rating depends on the complete assembly, including framing, fasteners, joints, insulation, and installation details.


Some rated walls and ceilings require two or more layers of gypsum board. We install each layer according to the listed assembly, which may specify staggered joints, separate fastening patterns, particular board types, and insulation within the framing cavity.
These details help the complete system meet its stated fire-resistance rating.
Type C board is designed for fire-rated assemblies that call for its particular performance and construction details. Its core formulation differs from Type X, and the two products are not interchangeable by default.
We check the project plans and the assembly listing to confirm the required board type, thickness, number of layers, and framing configuration.
Types of Fire-Resistant Drywall We Install in Missouri City, TX


Where a room needs both moisture-resistant surfaces and a rated assembly, we verify that the selected board is approved for the specified use. Product names and features alone do not establish that a board meets the fire-resistance requirements of a wall or ceiling.
The assembly listing and manufacturer’s installation instructions determine whether the product is suitable.
Multi-Layer Fire-Rated Assemblies
Type C Fire-Resistant Drywall
Moisture- and Fire-Resistant Combination Boards




Sound- and Fire-Rated Drywall Systems
A wall can be designed to address both sound transfer and fire separation, but both goals depend on the full assembly. Board layers, stud layout, cavity insulation, resilient channels, sealants, and perimeter details can affect acoustic performance and fire rating.
We follow the assembly requirements so one feature does not compromise the other.
Fire-Resistant Drywall Installation by Property Type
Residential Fire-Rated Drywall (Homes, Attached Garages, Additions)






In a home, fire-rated drywall commonly protects the separation between an attached garage and living space. The garage ceiling may also need a rated assembly when a room sits above it. Exterior-facing garage walls and the house-to-garage separation serve different purposes, so we confirm which surfaces require protection before selecting materials.
New Construction Fire-Rated Drywall (Builders and General Contractors)
On new construction, we coordinate with builders and general contractors before board installation to confirm wall types, ceiling assemblies, and transitions shown on the plans. Early coordination helps align framing, utilities, and inspection timing. We verify that the substrate and framing suit the specified system and flag conflicts, such as ducts or conduits routed through rated boundaries, for resolution before closure.
Multi-Family Fire-Rated Drywall (Townhomes, Duplexes, Apartments)
In townhomes, duplexes, and apartments, rated walls and floor-ceiling assemblies help separate units and shared spaces. We identify the assembly requirements for party walls, corridors, stairwells, and service areas before installation. Requirements depend on the building’s design, occupancy, and adopted codes, so the plans and local authority’s direction matter.
Commercial Fire-Rated Drywall (Offices, Restaurants, Retail, Medical Suites)


Commercial projects may require rated partitions around tenant spaces, exit routes, mechanical rooms, and other designated areas. The requirements vary with occupancy, building layout, and the approved plans. We use the project documents to identify the required rating and assembly before installing board in offices, restaurants, retail spaces, or medical suites.
Drywall Hanging, Taping & Mudding (Fire-Taping and Finish Levels)


We install Type X or Type C board according to the assembly requirements, securing it to the framing with the specified fastener type, spacing, and layout. Staggered joints and carefully fitted sheets help maintain continuity across the wall or ceiling.
Related Drywall & Finishing Services


Fire-Stopping & Sealing Around Pipes, Wires and Ducts
Pipes, wiring, and ducts that pass through a rated wall or ceiling need compatible fire-stop systems designed for the specific opening and assembly.
We check the penetration size, materials, and location before selecting a sealant or other listed fire-stop product. Ordinary joint compound or general-purpose caulk does not serve as a substitute for a specified fire-stop system.


Fire-Rated Insulation (Mineral Wool)
Mineral wool may form part of a rated wall or ceiling assembly, depending on its tested design. We confirm the required product, thickness, density, and placement against the assembly details instead of treating insulation as interchangeable.
Gaps, compression, or missing sections can affect how the completed system matches its design.


Texture Matching & Painting
Texture and paint complete the visible surface, but finishing work must follow the required treatment of rated joints and penetrations. We match the existing texture where practical, then prepare the surface for primer and paint.
Lighting and viewing angle affect how noticeable a texture difference appears, so we assess the repaired area in its room context.
Frequently asked questions
How much does fire-rated drywall installation cost in Missouri City, TX?
We price each project based on the area, Type X or Type C board, framing, layers, finishing, and firestopping around openings and penetrations. A site visit helps us identify the required assembly and provide a project-specific estimate.
What is the difference between Type X and Type C drywall for walls and ceilings?
Both are fire-resistant gypsum boards, but their performance depends on the tested assembly. Type C boards are formulated for some assemblies that require greater fire resistance or specific ceiling designs. We select the board specified by the assembly design and applicable code, rather than treating the types as interchangeable.
Is Type X drywall fireproof, or does it only slow the spread of fire?
Type X drywall is not fireproof. Its fire-resistant core helps an approved wall or ceiling assembly resist fire and heat for a tested period, giving occupants more time to respond. The rating applies to the complete assembly, not to the board alone.
What installation requirements must a wall or ceiling meet to achieve a one-hour fire rating?
A one-hour rating applies to a tested assembly. The design specifies details such as board type and thickness, number of layers, framing, fastener type and spacing, joint treatment, and protection for penetrations. Following a listed assembly, such as a UL fire-rated wall design, is essential to achieving its stated rating.
Where is fire-resistant drywall required in Missouri City homes?
Requirements depend on the building code and the home’s layout. Common locations include walls and ceilings separating an attached garage from living space, and certain furnace or utility room walls. Check the project requirements with the Missouri City building department before work begins.
How can I verify that a drywall contractor installs code-compliant fire-rated assemblies?
Ask us to identify the assembly design and board specifications for each rated wall or ceiling. You can also check that the installation matches the design’s framing, fasteners, joints, and firestopping details, and confirm permit and inspection requirements with the local building department.

Missouri City Drywall
8585 Sienna Springs blvd
Missouri City, Texas 77459
(346) 483-7149
© 2025 Missouri City Drywall, Tx